{"product_id":"gree-u-match-13-2kw-under-ceiling-heat-pump","title":"Gree U-Match 13.2kW Under-Ceiling Heat Pump","description":"\u003cp\u003eA Gree U-Match under-ceiling (floor \/ ceiling) R32 inverter heat pump. The indoor unit hangs under the ceiling or sits low on a wall, so it suits rooms where there's no space for a high wall unit or ceiling cassette. It runs on Gree's U-Match outdoor unit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFree freight NZ wide.\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSuspends under a ceiling or mounts low on a wall, where wall or ceiling-cavity space is limited\u003c\/li\u003e\n\u003cli\u003eAutomatic louvre control between heating and cooling; the louvre closes fully when the unit is off\u003c\/li\u003e\n\u003cli\u003ePowerful airflow with auto restart and auto changeover\u003c\/li\u003e\n\u003cli\u003eUses Gree's U-Match R32 inverter outdoor unit, the same outdoor unit as the U-Match ducted and cassette systems\u003c\/li\u003e\n\u003cli\u003eWired wall controller supplied as standard; wireless remote and Wi-Fi (Gree ME31-00\/C6 module) optional\u003c\/li\u003e\n\u003cli\u003eGood for shops, restaurants, hallways, offices and server or electrical rooms\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePerformance\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity\u003c\/th\u003e\n\u003ctd\u003e13.2 kW (range 6.35 to 16 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeating capacity\u003c\/th\u003e\n\u003ctd\u003e16.0 kW (range 4.5 to 17 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRating basis\u003c\/th\u003e\n\u003ctd\u003eGree's published under-ceiling ratings (Gree NZ U-Match brochure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSize on Gree NZ price list\u003c\/th\u003e\n\u003ctd\u003eListed as 14.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower input (cooling \/ heating)\u003c\/th\u003e\n\u003ctd\u003e4.12 \/ 4.30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling efficiency (EER)\u003c\/th\u003e\n\u003ctd\u003e3.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeating efficiency (COP)\u003c\/th\u003e\n\u003ctd\u003e3.72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIndoor airflow\u003c\/th\u003e\n\u003ctd\u003e638 L\/s (rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIndoor sound pressure\u003c\/th\u003e\n\u003ctd\u003e46 to 52 dB(A) (low to super high; medium 49, high 51)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutdoor sound pressure\u003c\/th\u003e\n\u003ctd\u003e59 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutdoor sound power\u003c\/th\u003e\n\u003ctd\u003e72 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eElectrical\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e220–240 V, 50 Hz, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended circuit breaker\u003c\/th\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIndoor–outdoor control wiring\u003c\/th\u003e\n\u003ctd\u003e2 × 0.75 mm² communication cable; 3 × 1.0 mm² power interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eController\u003c\/th\u003e\n\u003ctd\u003eWired wall controller supplied; YAP1F6 wireless remote optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and weights\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIndoor unit (W × H × D)\u003c\/th\u003e\n\u003ctd\u003e1570 × 235 × 665 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIndoor unit net weight\u003c\/th\u003e\n\u003ctd\u003e42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutdoor unit (W × H × D)\u003c\/th\u003e\n\u003ctd\u003e900 × 1260 × 340 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutdoor unit net weight\u003c\/th\u003e\n\u003ctd\u003e90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRefrigerant\u003c\/th\u003e\n\u003ctd\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFactory refrigerant charge\u003c\/th\u003e\n\u003ctd\u003e2.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePipe connections\u003c\/th\u003e\n\u003ctd\u003eIndoor 9.52 \/ 15.88 mm (3\/8″ \/ 5\/8″); outdoor unit 3\/8″ \/ 5\/8″ (liquid \/ gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePre-charged pipe length\u003c\/th\u003e\n\u003ctd\u003e15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMax pipe length\u003c\/th\u003e\n\u003ctd\u003e75 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMax height difference\u003c\/th\u003e\n\u003ctd\u003e30 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAdditional refrigerant\u003c\/th\u003e\n\u003ctd\u003e25 g\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutdoor operating range, cooling\u003c\/th\u003e\n\u003ctd\u003e-15 to 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutdoor operating range, heating\u003c\/th\u003e\n\u003ctd\u003e-15 to 24 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrain connection\u003c\/th\u003e\n\u003ctd\u003eΦ17 mm × 1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eModel and warranty\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eGree\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRange\u003c\/th\u003e\n\u003ctd\u003eU-Match Under-Ceiling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eUnder-ceiling split system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIndoor unit model\u003c\/th\u003e\n\u003ctd\u003eGUD140ZD\/B-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutdoor unit model\u003c\/th\u003e\n\u003ctd\u003eGUD140W1\/NhC-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e6 years parts and labour (Gree NZ residential warranty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e6 years parts and labour from the original date of purchase, under Gree NZ's residential warranty (Under-ceiling, GUD-ZD series).\u003c\/li\u003e\n\u003cli\u003eCovers defects in Gree's design, workmanship or materials. There's no separate compressor term: the compressor is covered as part of the unit for the same 6 years.\u003c\/li\u003e\n\u003cli\u003eConditions: installed, used and maintained in New Zealand; serviced by a qualified refrigeration and air conditioning technician at least every 12 months; original purchaser only.\u003c\/li\u003e\n\u003cli\u003eNot covered: filters, batteries and other consumables, cosmetic damage, faulty installation or wiring, corrosive atmospheres, or units fitted in a boat, caravan or other moveable dwelling.\u003c\/li\u003e\n\u003cli\u003eCommercial jobs: Gree NZ's card is for residential products and doesn't give a separate commercial term. Ask us before ordering for a commercial install.\u003c\/li\u003e\n\u003cli\u003eYour rights under the Consumer Guarantees Act 1993 aren't affected.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMust be installed by a licensed installer. Refrigerant work needs a certified refrigeration technician, and wiring needs a registered electrician.\u003c\/li\u003e\n\u003cli\u003eCheck the ceiling or wall can carry the indoor unit's weight, and leave room around it for airflow and servicing.\u003c\/li\u003e\n\u003cli\u003eIndoor and outdoor pipe sizes can differ on some sizes: the installer should check the fittings before running pipe.\u003c\/li\u003e\n\u003cli\u003ePre-charged for 15 m of pipe; add 25 g\/m beyond that.\u003c\/li\u003e\n\u003cli\u003eMax pipe length 75 m and max height difference 30 m between indoor and outdoor units.\u003c\/li\u003e\n\u003cli\u003eRecommended circuit breaker: 40 A.\u003c\/li\u003e\n\u003cli\u003eBook a service at least every 12 months by a qualified refrigeration technician: Gree NZ's warranty needs it.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat size do I need?\u003c\/strong\u003e\u003cbr\u003eIt depends on the room size, insulation, windows and climate. Send us your room sizes and we'll help you pick the right capacity.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs the outdoor unit included?\u003c\/strong\u003e\u003cbr\u003eYes. This is a complete split system: the under-ceiling indoor unit and the U-Match outdoor unit together.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I control it from my phone?\u003c\/strong\u003e\u003cbr\u003eWi-Fi is an optional extra (Gree's ME31-00\/C6 module). A wired wall controller comes as standard.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill it heat in a cold winter?\u003c\/strong\u003e\u003cbr\u003eGree rates the outdoor heating operating range at -15 to 24 °C.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does it have?\u003c\/strong\u003e\u003cbr\u003e6 years parts and labour from Gree NZ, as long as it's serviced at least every 12 months by a qualified technician.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I install it myself?\u003c\/strong\u003e\u003cbr\u003eNo. Heat pumps must be installed by a licensed installer, and refrigerant work needs a certified technician.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications are Gree's published figures and may change as products are improved.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your room sizes or a photo of the job and we'll help you pick the right heat pump.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Gree-U-Match-13-2kW-Under-Ceiling-Heat-Pump-HVACHub-Technical-Data-v3.pdf?v=1795667528\" target=\"_blank\" rel=\"noopener\"\u003eTechnical data sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Gree-UMatch-Brochure-2021-HVACHub.pdf?v=1795670023\" target=\"_blank\" rel=\"noopener\"\u003eGree brochure (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"Gree","offers":[{"title":"Default Title","offer_id":49501640360054,"sku":"HH-GREE-GUD140ZD-B-S","price":9999.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/gree-u-match-13-2kw-under-ceiling-heat-pump.jpg?v=1795667579","url":"https:\/\/hvachub.co.nz\/products\/gree-u-match-13-2kw-under-ceiling-heat-pump","provider":"HVAC Hub","version":"1.0","type":"link"}