{"title":"Home Ventilation – Heat Transfer Units","description":"\u003cp\u003eA heat transfer kit takes spare heat from your warmest room, usually where the fire or heat pump is, and moves it to cold bedrooms and back rooms through ducting in the ceiling. Kits are available for 1, 2, 3 or 4 rooms, with or without a thermostat that switches the fan on when the room gets warm. Everything you need is in the box, making it a popular DIY project. Choose your kit by the number of rooms.\u003c\/p\u003e","products":[{"product_id":"heat-transfer-kit-1-room","title":"Heat Transfer Kit – 1 Room","description":"\u003cp\u003eMoves spare warm air from your warmest room (usually where the fire or heat pump is) to a cooler room, spreading heat through the house for little running cost.\u003c\/p\u003e\n\u003cp\u003eThis kit is supplied for a 1-room install and includes the parts listed below. The house-plan graphic on the product tile is illustrative branding; the kit contents are as listed.\u003c\/p\u003e\n\u003ch3\u003eWhat's in the kit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2 × Insulated flex 150\u003c\/li\u003e\n\u003cli\u003e2 × Ceiling diffuser with insect screen 150 mm\u003c\/li\u003e\n\u003cli\u003e1 × Reinforced foil tape 3 m\u003c\/li\u003e\n\u003cli\u003e1 × Axial in-line fan 150 dia (with fixing feet) 87 L\/s FID\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e150 mm axial in-line fan: 220–240 V 50\/60 Hz, 24 W, 87 L\/s (FID, as catalogued), IPX4.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003cp\u003eFan figures are for the catalogued kit fan, not a measured system airflow.\u003c\/p\u003e\n\u003ch3\u003eFitting tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical connection must be done by a registered electrician in NZ.\u003c\/li\u003e\n\u003cli\u003eKeep duct runs short and straight to get the rated airflow.\u003c\/li\u003e\n\u003cli\u003eThe intake is taken from the warm room — this is a heat-transfer kit, not an extract fan to outside.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need an electrician?\u003c\/strong\u003e\u003cbr\u003eYes – mains wiring must be done by a registered electrician.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it work?\u003c\/strong\u003e\u003cbr\u003eA fan moves spare heat from your warmest room into cooler rooms through insulated duct and ceiling diffusers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much power does the fan use?\u003c\/strong\u003e\u003cbr\u003eThe kit fan is rated at 24 W.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Heat-Transfer-Kit-1-Room-HVACHub-Limited-Technical-Data.pdf?v=1794983259\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098685481078,"sku":"HH-HH01","price":367.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-hh-sa-hh01-tile.jpg?v=1794459143"},{"product_id":"heat-transfer-kit-1-room-with-thermostat","title":"Heat Transfer Kit – 1 Room with Thermostat","description":"\u003cp\u003eMoves spare warm air from your warmest room (usually where the fire or heat pump is) to a cooler room, spreading heat through the house for little running cost.\u003c\/p\u003e\n\u003cp\u003eThis kit is supplied for a 1-room install with a thermostat and includes the parts listed below. The house-plan graphic on the product tile is illustrative branding; the kit contents are as listed.\u003c\/p\u003e\n\u003ch3\u003eWhat's in the kit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2 × Insulated flex 150\u003c\/li\u003e\n\u003cli\u003e2 × Ceiling diffuser with insect screen 150 mm\u003c\/li\u003e\n\u003cli\u003e1 × Reinforced foil tape 3 m\u003c\/li\u003e\n\u003cli\u003e1 × Axial in-line fan 150 dia (with fixing feet) 87 L\/s FID\u003c\/li\u003e\n\u003cli\u003e1 × Fan thermostat c\/w on\/off switch 6 amp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e150 mm axial in-line fan: 220–240 V 50\/60 Hz, 24 W, 87 L\/s (FID, as catalogued), IPX4.\u003c\/li\u003e\n\u003cli\u003eFan thermostat with on\/off switch. Switch rating 6 A. A published wiring diagram for this thermostat was not available, so none is shown here.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFan figures are for the catalogued kit fan, not a measured system airflow.\u003c\/p\u003e\n\u003ch3\u003eFitting tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical connection must be done by a registered electrician in NZ.\u003c\/li\u003e\n\u003cli\u003eKeep duct runs short and straight to get the rated airflow.\u003c\/li\u003e\n\u003cli\u003eThe intake is taken from the warm room — this is a heat-transfer kit, not an extract fan to outside.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need an electrician?\u003c\/strong\u003e\u003cbr\u003eYes – mains wiring must be done by a registered electrician.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it work?\u003c\/strong\u003e\u003cbr\u003eA fan moves spare heat from your warmest room into cooler rooms through insulated duct and ceiling diffusers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much power does the fan use?\u003c\/strong\u003e\u003cbr\u003eThe kit fan is rated at 24 W.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Heat-Transfer-Kit-1-Room-with-Thermostat-HVACHub-Limited-Technical-Data.pdf?v=1794983259\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098686103670,"sku":"HH-HH01TH","price":455.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-hh-sa-hh01th-tile.jpg?v=1794459143"},{"product_id":"heat-transfer-kit-2-rooms","title":"Heat Transfer Kit – 2 Rooms","description":"\u003cp\u003eMoves spare warm air from your warmest room (usually where the fire or heat pump is) to cooler bedrooms, spreading heat through the house for little running cost.\u003c\/p\u003e\n\u003cp\u003eThis kit is supplied for a 2-room install and includes the parts listed below. The house-plan graphic on the product tile is illustrative branding; the kit contents are as listed.\u003c\/p\u003e\n\u003ch3\u003eWhat's in the kit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4 × Insulated flex 150\u003c\/li\u003e\n\u003cli\u003e1 × Centrifugal in-line fan 150 dia, 128 L\/s FID\u003c\/li\u003e\n\u003cli\u003e3 × Ceiling diffuser with insect screen 150 mm\u003c\/li\u003e\n\u003cli\u003e1 × Reinforced foil tape 6 m\u003c\/li\u003e\n\u003cli\u003e1 × Insulated plastic Y-body 200 \/ 150 \/ 150\u003c\/li\u003e\n\u003cli\u003e2 × Spigot 150\u003c\/li\u003e\n\u003cli\u003e1 × Reducing spigot 200–150\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e150 mm centrifugal in-line fan: 230 V 50 Hz, 0.35 A, 80 W, 127.8 L\/s, IP44.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003cp\u003eFan figures are for the catalogued kit fan, not a measured system airflow.\u003c\/p\u003e\n\u003ch3\u003eFitting tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical connection must be done by a registered electrician in NZ.\u003c\/li\u003e\n\u003cli\u003eKeep duct runs short and straight to get the rated airflow.\u003c\/li\u003e\n\u003cli\u003eThe intake is taken from the warm room — this is a heat-transfer kit, not an extract fan to outside.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need an electrician?\u003c\/strong\u003e\u003cbr\u003eYes – mains wiring must be done by a registered electrician.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it work?\u003c\/strong\u003e\u003cbr\u003eA fan moves spare heat from your warmest room into cooler rooms through insulated duct and ceiling diffusers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much power does the fan use?\u003c\/strong\u003e\u003cbr\u003eThe kit fan is rated at 80 W.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Heat-Transfer-Kit-2-Rooms-HVACHub-Limited-Technical-Data.pdf?v=1794983259\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098686955638,"sku":"HH-HH02","price":735.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-hh-sa-hh02-tile.jpg?v=1794459143"},{"product_id":"heat-transfer-kit-2-rooms-with-thermostat","title":"Heat Transfer Kit – 2 Rooms with Thermostat","description":"\u003cp\u003eMoves spare warm air from your warmest room (usually where the fire or heat pump is) to cooler bedrooms, spreading heat through the house for little running cost.\u003c\/p\u003e\n\u003cp\u003eThis kit is supplied for a 2-room install with a thermostat and includes the parts listed below. The house-plan graphic on the product tile is illustrative branding; the kit contents are as listed.\u003c\/p\u003e\n\u003ch3\u003eWhat's in the kit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4 × Insulated flex 150\u003c\/li\u003e\n\u003cli\u003e1 × Centrifugal in-line fan 150 dia, 128 L\/s FID\u003c\/li\u003e\n\u003cli\u003e3 × Ceiling diffuser with insect screen 150 mm\u003c\/li\u003e\n\u003cli\u003e1 × Reinforced foil tape 6 m\u003c\/li\u003e\n\u003cli\u003e1 × Y Branch 150 \/ 150 \/ 150 Plain Plastic\u003c\/li\u003e\n\u003cli\u003e1 × Fan thermostat c\/w on\/off switch 6 amp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e150 mm centrifugal in-line fan: 230 V 50 Hz, 0.35 A, 80 W, 127.8 L\/s, IP44.\u003c\/li\u003e\n\u003cli\u003eFan thermostat with on\/off switch. Switch rating 6 A. A published wiring diagram for this thermostat was not available, so none is shown here.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFan figures are for the catalogued kit fan, not a measured system airflow.\u003c\/p\u003e\n\u003ch3\u003eFitting tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical connection must be done by a registered electrician in NZ.\u003c\/li\u003e\n\u003cli\u003eKeep duct runs short and straight to get the rated airflow.\u003c\/li\u003e\n\u003cli\u003eThe intake is taken from the warm room — this is a heat-transfer kit, not an extract fan to outside.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need an electrician?\u003c\/strong\u003e\u003cbr\u003eYes – mains wiring must be done by a registered electrician.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it work?\u003c\/strong\u003e\u003cbr\u003eA fan moves spare heat from your warmest room into cooler rooms through insulated duct and ceiling diffusers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much power does the fan use?\u003c\/strong\u003e\u003cbr\u003eThe kit fan is rated at 80 W.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Heat-Transfer-Kit-2-Rooms-with-Thermostat-HVACHub-Limited-Technical-Data.pdf?v=1794983259\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098687545462,"sku":"HH-HH02TH","price":794.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-hh-sa-hh02th-tile.jpg?v=1794459143"},{"product_id":"heat-transfer-kit-3-rooms","title":"Heat Transfer Kit – 3 Rooms","description":"\u003cp\u003eMoves spare warm air from your warmest room (usually where the fire or heat pump is) to cooler bedrooms, spreading heat through the house for little running cost.\u003c\/p\u003e\n\u003cp\u003eThis kit is supplied for a 3-room install and includes the parts listed below. The house-plan graphic on the product tile is illustrative branding; the kit contents are as listed.\u003c\/p\u003e\n\u003ch3\u003eWhat's in the kit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3 × Insulated flex 150\u003c\/li\u003e\n\u003cli\u003e2 × Insulated flex 200\u003c\/li\u003e\n\u003cli\u003e1 × Round Ceiling Diffuser 200 dia\u003c\/li\u003e\n\u003cli\u003e3 × Ceiling diffuser with insect screen 150 mm\u003c\/li\u003e\n\u003cli\u003e1 × Reinforced foil tape 6 m\u003c\/li\u003e\n\u003cli\u003e1 × Centrifugal in-line fan 200 dia, 217 L\/s FID\u003c\/li\u003e\n\u003cli\u003e1 × 200 Diameter Dry Matic Collar\u003c\/li\u003e\n\u003cli\u003e1 × Insulated branch take-off 200 \/ 150 \/ 150 \/ 150, assembled\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e200 mm centrifugal in-line fan: 230 V 50 Hz, 0.47 A, 107 W, 216.7 L\/s, IP44.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003cp\u003eFan figures are for the catalogued kit fan, not a measured system airflow.\u003c\/p\u003e\n\u003ch3\u003eFitting tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical connection must be done by a registered electrician in NZ.\u003c\/li\u003e\n\u003cli\u003eKeep duct runs short and straight to get the rated airflow.\u003c\/li\u003e\n\u003cli\u003eThe intake is taken from the warm room — this is a heat-transfer kit, not an extract fan to outside.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need an electrician?\u003c\/strong\u003e\u003cbr\u003eYes – mains wiring must be done by a registered electrician.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it work?\u003c\/strong\u003e\u003cbr\u003eA fan moves spare heat from your warmest room into cooler rooms through insulated duct and ceiling diffusers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much power does the fan use?\u003c\/strong\u003e\u003cbr\u003eThe kit fan is rated at 107 W.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Heat-Transfer-Kit-3-Rooms-HVACHub-Limited-Technical-Data.pdf?v=1794983259\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098688233590,"sku":"HH-HH03","price":1029.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-hh-sa-hh03-tile.jpg?v=1794459143"},{"product_id":"heat-transfer-kit-3-rooms-with-thermostat","title":"Heat Transfer Kit – 3 Rooms with Thermostat","description":"\u003cp\u003eMoves spare warm air from your warmest room (usually where the fire or heat pump is) to cooler bedrooms, spreading heat through the house for little running cost.\u003c\/p\u003e\n\u003cp\u003eThis kit is supplied for a 3-room install with a thermostat and includes the parts listed below. The house-plan graphic on the product tile is illustrative branding; the kit contents are as listed.\u003c\/p\u003e\n\u003ch3\u003eWhat's in the kit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3 × Insulated flex 150\u003c\/li\u003e\n\u003cli\u003e2 × Insulated flex 200\u003c\/li\u003e\n\u003cli\u003e1 × Round Ceiling Diffuser 200 dia\u003c\/li\u003e\n\u003cli\u003e3 × Ceiling diffuser with insect screen 150 mm\u003c\/li\u003e\n\u003cli\u003e1 × Reinforced foil tape 6 m\u003c\/li\u003e\n\u003cli\u003e1 × Centrifugal in-line fan 200 dia, 217 L\/s FID\u003c\/li\u003e\n\u003cli\u003e1 × 200 Diameter Dry Matic Collar\u003c\/li\u003e\n\u003cli\u003e1 × Insulated branch take-off 200 \/ 150 \/ 150 \/ 150, assembled\u003c\/li\u003e\n\u003cli\u003e1 × Fan thermostat c\/w on\/off switch 6 amp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e200 mm centrifugal in-line fan: 230 V 50 Hz, 0.47 A, 107 W, 216.7 L\/s, IP44.\u003c\/li\u003e\n\u003cli\u003eFan thermostat with on\/off switch. Switch rating 6 A. A published wiring diagram for this thermostat was not available, so none is shown here.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFan figures are for the catalogued kit fan, not a measured system airflow.\u003c\/p\u003e\n\u003ch3\u003eFitting tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical connection must be done by a registered electrician in NZ.\u003c\/li\u003e\n\u003cli\u003eKeep duct runs short and straight to get the rated airflow.\u003c\/li\u003e\n\u003cli\u003eThe intake is taken from the warm room — this is a heat-transfer kit, not an extract fan to outside.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need an electrician?\u003c\/strong\u003e\u003cbr\u003eYes – mains wiring must be done by a registered electrician.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it work?\u003c\/strong\u003e\u003cbr\u003eA fan moves spare heat from your warmest room into cooler rooms through insulated duct and ceiling diffusers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much power does the fan use?\u003c\/strong\u003e\u003cbr\u003eThe kit fan is rated at 107 W.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Heat-Transfer-Kit-3-Rooms-with-Thermostat-HVACHub-Limited-Technical-Data.pdf?v=1794983259\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098688823414,"sku":"HH-HH03TH","price":1118.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-hh-sa-hh03th-tile.jpg?v=1794459143"},{"product_id":"heat-transfer-kit-4-rooms","title":"Heat Transfer Kit – 4 Rooms","description":"\u003cp\u003eMoves spare warm air from your warmest room (usually where the fire or heat pump is) to cooler bedrooms, spreading heat through the house for little running cost.\u003c\/p\u003e\n\u003cp\u003eThis kit is supplied for a 4-room install and includes the parts listed below. The house-plan graphic on the product tile is illustrative branding; the kit contents are as listed.\u003c\/p\u003e\n\u003ch3\u003eWhat's in the kit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Insulated Flex 200 × 6 m R0.6\u003c\/li\u003e\n\u003cli\u003e3 × Insulated flex 200\u003c\/li\u003e\n\u003cli\u003e1 × Round Ceiling Diffuser 200 dia\u003c\/li\u003e\n\u003cli\u003e4 × Insulated flex 150\u003c\/li\u003e\n\u003cli\u003e4 × Ceiling diffuser with insect screen 150 mm\u003c\/li\u003e\n\u003cli\u003e2 × Reinforced foil tape 6 m\u003c\/li\u003e\n\u003cli\u003e1 × Centrifugal in-line fan 200 dia, 217 L\/s FID\u003c\/li\u003e\n\u003cli\u003e1 × 200 Diameter Dry Matic Collar\u003c\/li\u003e\n\u003cli\u003e2 × Insulated plastic Y-body 200 \/ 150 \/ 150\u003c\/li\u003e\n\u003cli\u003e4 × Spigot 150\u003c\/li\u003e\n\u003cli\u003e2 × Insulated Plastic Y-Body Only 250 \/ 200 \/ 200\u003c\/li\u003e\n\u003cli\u003e4 × Spigot 200\u003c\/li\u003e\n\u003cli\u003e1 × Reducing spigot 250–200\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e200 mm centrifugal in-line fan: 230 V 50 Hz, 0.47 A, 107 W, 216.7 L\/s, IP44.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003cp\u003eFan figures are for the catalogued kit fan, not a measured system airflow.\u003c\/p\u003e\n\u003ch3\u003eFitting tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical connection must be done by a registered electrician in NZ.\u003c\/li\u003e\n\u003cli\u003eKeep duct runs short and straight to get the rated airflow.\u003c\/li\u003e\n\u003cli\u003eThe intake is taken from the warm room — this is a heat-transfer kit, not an extract fan to outside.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need an electrician?\u003c\/strong\u003e\u003cbr\u003eYes – mains wiring must be done by a registered electrician.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it work?\u003c\/strong\u003e\u003cbr\u003eA fan moves spare heat from your warmest room into cooler rooms through insulated duct and ceiling diffusers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much power does the fan use?\u003c\/strong\u003e\u003cbr\u003eThe kit fan is rated at 107 W.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Heat-Transfer-Kit-4-Rooms-HVACHub-Limited-Technical-Data.pdf?v=1794983258\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098689544310,"sku":"HH-HH04","price":1501.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-hh-sa-hh04-tile.jpg?v=1794459143"},{"product_id":"heat-transfer-kit-4-rooms-with-thermostat","title":"Heat Transfer Kit – 4 Rooms with Thermostat","description":"\u003cp\u003eMoves spare warm air from your warmest room (usually where the fire or heat pump is) to cooler bedrooms, spreading heat through the house for little running cost.\u003c\/p\u003e\n\u003cp\u003eThis kit is supplied for a 4-room install with a thermostat and includes the parts listed below. The house-plan graphic on the product tile is illustrative branding; the kit contents are as listed.\u003c\/p\u003e\n\u003ch3\u003eWhat's in the kit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Insulated Flex 200 × 6 m R0.6\u003c\/li\u003e\n\u003cli\u003e3 × Insulated flex 200\u003c\/li\u003e\n\u003cli\u003e1 × Round Ceiling Diffuser 200 dia\u003c\/li\u003e\n\u003cli\u003e4 × Insulated flex 150\u003c\/li\u003e\n\u003cli\u003e4 × Ceiling diffuser with insect screen 150 mm\u003c\/li\u003e\n\u003cli\u003e2 × Reinforced foil tape 6 m\u003c\/li\u003e\n\u003cli\u003e1 × Centrifugal in-line fan 200 dia, 217 L\/s FID\u003c\/li\u003e\n\u003cli\u003e1 × Y Branch 150 \/ 150 \/ 150 Plain Plastic\u003c\/li\u003e\n\u003cli\u003e1 × 200 Diameter Dry Matic Collar\u003c\/li\u003e\n\u003cli\u003e2 × Insulated plastic Y-body 200 \/ 150 \/ 150\u003c\/li\u003e\n\u003cli\u003e4 × Spigot 150\u003c\/li\u003e\n\u003cli\u003e2 × Spigot 200\u003c\/li\u003e\n\u003cli\u003e1 × Fan thermostat c\/w on\/off switch 6 amp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e200 mm centrifugal in-line fan: 230 V 50 Hz, 0.47 A, 107 W, 216.7 L\/s, IP44.\u003c\/li\u003e\n\u003cli\u003eFan thermostat with on\/off switch. Switch rating 6 A. A published wiring diagram for this thermostat was not available, so none is shown here.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFan figures are for the catalogued kit fan, not a measured system airflow.\u003c\/p\u003e\n\u003ch3\u003eFitting tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical connection must be done by a registered electrician in NZ.\u003c\/li\u003e\n\u003cli\u003eKeep duct runs short and straight to get the rated airflow.\u003c\/li\u003e\n\u003cli\u003eThe intake is taken from the warm room — this is a heat-transfer kit, not an extract fan to outside.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need an electrician?\u003c\/strong\u003e\u003cbr\u003eYes – mains wiring must be done by a registered electrician.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it work?\u003c\/strong\u003e\u003cbr\u003eA fan moves spare heat from your warmest room into cooler rooms through insulated duct and ceiling diffusers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much power does the fan use?\u003c\/strong\u003e\u003cbr\u003eThe kit fan is rated at 107 W.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Heat-Transfer-Kit-4-Rooms-with-Thermostat-HVACHub-Limited-Technical-Data.pdf?v=1794983258\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098690330742,"sku":"HH-HH04TH","price":1589.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-hh-sa-hh04th-tile.jpg?v=1794459143"},{"product_id":"heat-transfer-kit-1-room-with-thermostat-alternate-diffusers","title":"Heat Transfer Kit – 1 Room with Thermostat (Alternate Diffusers)","description":"\u003cp\u003eMoves spare warm air from your warmest room (usually where the fire or heat pump is) to a cooler room, spreading heat through the house for little running cost.\u003c\/p\u003e\n\u003cp\u003eThis kit is supplied for a 1-room install with a thermostat, with alternate diffusers and includes the parts listed below. The house-plan graphic on the product tile is illustrative branding; the kit contents are as listed.\u003c\/p\u003e\n\u003ch3\u003eWhat's in the kit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2 × Insulated flex 150\u003c\/li\u003e\n\u003cli\u003e1 × Downjet diffuser 150 dia\u003c\/li\u003e\n\u003cli\u003e1 × Round Ceiling Diffuser 150 dia\u003c\/li\u003e\n\u003cli\u003e1 × Fan thermostat c\/w on\/off switch 6 amp\u003c\/li\u003e\n\u003cli\u003e1 × Reinforced foil tape 3 m\u003c\/li\u003e\n\u003cli\u003e1 × Axial in-line fan 150 dia (with fixing feet) 87 L\/s FID\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e150 mm axial in-line fan: 220–240 V 50\/60 Hz, 24 W, 87 L\/s (FID, as catalogued), IPX4.\u003c\/li\u003e\n\u003cli\u003eFan thermostat with on\/off switch. Switch rating 6 A. A published wiring diagram for this thermostat was not available, so none is shown here.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFan figures are for the catalogued kit fan, not a measured system airflow.\u003c\/p\u003e\n\u003ch3\u003eFitting tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical connection must be done by a registered electrician in NZ.\u003c\/li\u003e\n\u003cli\u003eKeep duct runs short and straight to get the rated airflow.\u003c\/li\u003e\n\u003cli\u003eThe intake is taken from the warm room — this is a heat-transfer kit, not an extract fan to outside.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need an electrician?\u003c\/strong\u003e\u003cbr\u003eYes – mains wiring must be done by a registered electrician.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it work?\u003c\/strong\u003e\u003cbr\u003eA fan moves spare heat from your warmest room into cooler rooms through insulated duct and ceiling diffusers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much power does the fan use?\u003c\/strong\u003e\u003cbr\u003eThe kit fan is rated at 24 W.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Heat-Transfer-Kit-1-Room-with-Thermostat-Alternate-Diffusers-HVACHub-Limited-Technical-Data.pdf?v=1794983258\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098866950262,"sku":"HH-PMHH01TH","price":514.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-hh-sa-pmhh01th-tile.jpg?v=1794459143"},{"product_id":"heat-transfer-kit-2-rooms-with-thermostat-alternate-diffusers","title":"Heat Transfer Kit – 2 Rooms with Thermostat (Alternate Diffusers)","description":"\u003cp\u003eMoves spare warm air from your warmest room (usually where the fire or heat pump is) to cooler bedrooms, spreading heat through the house for little running cost.\u003c\/p\u003e\n\u003cp\u003eThis kit is supplied for a 2-room install with a thermostat, with alternate diffusers and includes the parts listed below. The house-plan graphic on the product tile is illustrative branding; the kit contents are as listed.\u003c\/p\u003e\n\u003ch3\u003eWhat's in the kit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4 × Insulated flex 150\u003c\/li\u003e\n\u003cli\u003e1 × Centrifugal in-line fan 150 dia, 128 L\/s FID\u003c\/li\u003e\n\u003cli\u003e2 × Downjet diffuser 150 dia\u003c\/li\u003e\n\u003cli\u003e1 × Round Ceiling Diffuser 150 dia\u003c\/li\u003e\n\u003cli\u003e1 × Fan thermostat c\/w on\/off switch 6 amp\u003c\/li\u003e\n\u003cli\u003e1 × Reinforced foil tape 6 m\u003c\/li\u003e\n\u003cli\u003e1 × Insulated plastic Y-body 200 \/ 150 \/ 150\u003c\/li\u003e\n\u003cli\u003e2 × Spigot 150\u003c\/li\u003e\n\u003cli\u003e1 × Reducing spigot 200–150\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e150 mm centrifugal in-line fan: 230 V 50 Hz, 0.35 A, 80 W, 127.8 L\/s, IP44.\u003c\/li\u003e\n\u003cli\u003eFan thermostat with on\/off switch. Switch rating 6 A. A published wiring diagram for this thermostat was not available, so none is shown here.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFan figures are for the catalogued kit fan, not a measured system airflow.\u003c\/p\u003e\n\u003ch3\u003eFitting tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical connection must be done by a registered electrician in NZ.\u003c\/li\u003e\n\u003cli\u003eKeep duct runs short and straight to get the rated airflow.\u003c\/li\u003e\n\u003cli\u003eThe intake is taken from the warm room — this is a heat-transfer kit, not an extract fan to outside.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need an electrician?\u003c\/strong\u003e\u003cbr\u003eYes – mains wiring must be done by a registered electrician.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it work?\u003c\/strong\u003e\u003cbr\u003eA fan moves spare heat from your warmest room into cooler rooms through insulated duct and ceiling diffusers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much power does the fan use?\u003c\/strong\u003e\u003cbr\u003eThe kit fan is rated at 80 W.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Heat-Transfer-Kit-2-Rooms-with-Thermostat-Alternate-Diffusers-HVACHub-Limited-Technical-Data.pdf?v=1794983258\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098867540086,"sku":"HH-PMHH02TH","price":882.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-hh-sa-pmhh02th-tile.jpg?v=1794459143"},{"product_id":"heat-transfer-kit-3-rooms-with-thermostat-alternate-diffusers","title":"Heat Transfer Kit – 3 Rooms with Thermostat (Alternate Diffusers)","description":"\u003cp\u003eMoves spare warm air from your warmest room (usually where the fire or heat pump is) to cooler bedrooms, spreading heat through the house for little running cost.\u003c\/p\u003e\n\u003cp\u003eThis kit is supplied for a 3-room install with a thermostat, with alternate diffusers and includes the parts listed below. The house-plan graphic on the product tile is illustrative branding; the kit contents are as listed.\u003c\/p\u003e\n\u003ch3\u003eWhat's in the kit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3 × Insulated flex 150\u003c\/li\u003e\n\u003cli\u003e2 × Insulated flex 200\u003c\/li\u003e\n\u003cli\u003e1 × Round Ceiling Diffuser 200 dia\u003c\/li\u003e\n\u003cli\u003e3 × Downjet diffuser 150 dia\u003c\/li\u003e\n\u003cli\u003e1 × Reinforced foil tape 6 m\u003c\/li\u003e\n\u003cli\u003e1 × Centrifugal in-line fan 200 dia, 217 L\/s FID\u003c\/li\u003e\n\u003cli\u003e1 × 200 Diameter Dry Matic Collar\u003c\/li\u003e\n\u003cli\u003e1 × Insulated branch take-off 200 \/ 150 \/ 150 \/ 150, assembled\u003c\/li\u003e\n\u003cli\u003e1 × Fan thermostat c\/w on\/off switch 6 amp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e200 mm centrifugal in-line fan: 230 V 50 Hz, 0.47 A, 107 W, 216.7 L\/s, IP44.\u003c\/li\u003e\n\u003cli\u003eFan thermostat with on\/off switch. Switch rating 6 A. A published wiring diagram for this thermostat was not available, so none is shown here.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFan figures are for the catalogued kit fan, not a measured system airflow.\u003c\/p\u003e\n\u003ch3\u003eFitting tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical connection must be done by a registered electrician in NZ.\u003c\/li\u003e\n\u003cli\u003eKeep duct runs short and straight to get the rated airflow.\u003c\/li\u003e\n\u003cli\u003eThe intake is taken from the warm room — this is a heat-transfer kit, not an extract fan to outside.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need an electrician?\u003c\/strong\u003e\u003cbr\u003eYes – mains wiring must be done by a registered electrician.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it work?\u003c\/strong\u003e\u003cbr\u003eA fan moves spare heat from your warmest room into cooler rooms through insulated duct and ceiling diffusers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much power does the fan use?\u003c\/strong\u003e\u003cbr\u003eThe kit fan is rated at 107 W.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Heat-Transfer-Kit-3-Rooms-with-Thermostat-Alternate-Diffusers-HVACHub-Limited-Technical-Data.pdf?v=1794983258\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098868129910,"sku":"HH-PMHH03TH","price":1191.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-hh-sa-pmhh03th-tile.jpg?v=1794459143"},{"product_id":"heat-transfer-kit-4-rooms-with-thermostat-alternate-diffusers","title":"Heat Transfer Kit – 4 Rooms with Thermostat (Alternate Diffusers)","description":"\u003cp\u003eMoves spare warm air from your warmest room (usually where the fire or heat pump is) to cooler bedrooms, spreading heat through the house for little running cost.\u003c\/p\u003e\n\u003cp\u003eThis kit is supplied for a 4-room install with a thermostat, with alternate diffusers and includes the parts listed below. The house-plan graphic on the product tile is illustrative branding; the kit contents are as listed.\u003c\/p\u003e\n\u003ch3\u003eWhat's in the kit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Insulated Flex 200 × 6 m R0.6\u003c\/li\u003e\n\u003cli\u003e3 × Insulated flex 200\u003c\/li\u003e\n\u003cli\u003e1 × Round Ceiling Diffuser 200 dia\u003c\/li\u003e\n\u003cli\u003e4 × Insulated flex 150\u003c\/li\u003e\n\u003cli\u003e4 × Downjet diffuser 150 dia\u003c\/li\u003e\n\u003cli\u003e2 × Reinforced foil tape 6 m\u003c\/li\u003e\n\u003cli\u003e1 × Centrifugal in-line fan 200 dia, 217 L\/s FID\u003c\/li\u003e\n\u003cli\u003e1 × Fan thermostat c\/w on\/off switch 6 amp\u003c\/li\u003e\n\u003cli\u003e1 × 200 Diameter Dry Matic Collar\u003c\/li\u003e\n\u003cli\u003e2 × Insulated plastic Y-body 200 \/ 150 \/ 150\u003c\/li\u003e\n\u003cli\u003e4 × Spigot 150\u003c\/li\u003e\n\u003cli\u003e4 × Spigot 200\u003c\/li\u003e\n\u003cli\u003e1 × Insulated Plastic Y-Body Only 250 \/ 200 \/ 200\u003c\/li\u003e\n\u003cli\u003e1 × Reducing spigot 250–200\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e200 mm centrifugal in-line fan: 230 V 50 Hz, 0.47 A, 107 W, 216.7 L\/s, IP44.\u003c\/li\u003e\n\u003cli\u003eFan thermostat with on\/off switch. Switch rating 6 A. A published wiring diagram for this thermostat was not available, so none is shown here.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFan figures are for the catalogued kit fan, not a measured system airflow.\u003c\/p\u003e\n\u003ch3\u003eFitting tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical connection must be done by a registered electrician in NZ.\u003c\/li\u003e\n\u003cli\u003eKeep duct runs short and straight to get the rated airflow.\u003c\/li\u003e\n\u003cli\u003eThe intake is taken from the warm room — this is a heat-transfer kit, not an extract fan to outside.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need an electrician?\u003c\/strong\u003e\u003cbr\u003eYes – mains wiring must be done by a registered electrician.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it work?\u003c\/strong\u003e\u003cbr\u003eA fan moves spare heat from your warmest room into cooler rooms through insulated duct and ceiling diffusers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much power does the fan use?\u003c\/strong\u003e\u003cbr\u003eThe kit fan is rated at 107 W.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Heat-Transfer-Kit-4-Rooms-with-Thermostat-Alternate-Diffusers-HVACHub-Limited-Technical-Data.pdf?v=1794983258\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098868162678,"sku":"HH-PMHH04TH","price":1648.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-hh-sa-pmhh04th-tile.jpg?v=1794459143"}],"url":"https:\/\/hvachub.co.nz\/collections\/home-ventilation-heat-transfer-units.oembed","provider":"HVAC Hub","version":"1.0","type":"link"}