{"title":"Duct – Flexible Duct - Insulated","description":"\u003cp\u003eInsulated flexible duct is the most common duct in NZ homes, used for ducted heat pumps, heat transfer kits and heat recovery ventilation. The insulation stops heat loss and condensation as air travels through cold ceiling spaces. Choose your diameter to match your spigots, pick R0.6 or R1.0 insulation, or go acoustic for quieter bedrooms. Lengths of 3m and 6m make it easy to buy just what you need. Keep runs short and smooth, and support the duct every metre or so.\u003c\/p\u003e","products":[{"product_id":"hh-insulated-flex-50-300-x-6m-r1-0","title":"Insulated Flexible Duct 300 x 6m R1.0","description":"\u003cp\u003eInsulated flexible duct on a 6 m roll, for heat pump and ventilation ductwork.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner in plain packaging. One freight charge per order.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInside diameter\u003c\/th\u003e\n\u003ctd\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLength\u003c\/th\u003e\n\u003ctd\u003e6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInsulation\u003c\/th\u003e\n\u003ctd\u003eR1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDucting \u0026amp; Flexible Duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-300-x-6m-R1-0-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49095760871542,"sku":"HH-SA-PYFB506300","price":116.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9075534495862.jpg?v=1794802826"},{"product_id":"hh-insulated-flex-50-400-x-6m-r1-0","title":"Insulated Flexible Duct 400 x 6m R1.0","description":"\u003cp\u003eInsulated flexible duct on a 6 m roll, for heat pump and ventilation ductwork.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner in plain packaging. One freight charge per order.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInside diameter\u003c\/th\u003e\n\u003ctd\u003e400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLength\u003c\/th\u003e\n\u003ctd\u003e6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInsulation\u003c\/th\u003e\n\u003ctd\u003eR1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDucting \u0026amp; Flexible Duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-400-x-6m-R1-0-HVACHub-tile.pdf?v=1795301595\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49095760904310,"sku":"HH-SA-PYFB506400","price":161.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9075534528630.jpg?v=1794802826"},{"product_id":"hh-insulated-flex-50-450-x-6m-r1-0","title":"Insulated Flexible Duct 450 x 6m R1.0","description":"\u003cp\u003eInsulated flexible duct on a 6 m roll, for heat pump and ventilation ductwork.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner in plain packaging. One freight charge per order.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInside diameter\u003c\/th\u003e\n\u003ctd\u003e450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLength\u003c\/th\u003e\n\u003ctd\u003e6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInsulation\u003c\/th\u003e\n\u003ctd\u003eR1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDucting \u0026amp; Flexible Duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-450-x-6m-R1-0-HVACHub-tile.pdf?v=1795301595\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49095760937078,"sku":"HH-SA-PYFB506450","price":175.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9075534561398.jpg?v=1794802826"},{"product_id":"hh-insulated-flex-450-x-6m-r0-6","title":"Insulated Flexible Duct 450 x 6m R0.6","description":"\u003cp\u003eInsulated flexible duct on a 6 m roll, for heat pump and ventilation ductwork.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner in plain packaging. One freight charge per order.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInside diameter\u003c\/th\u003e\n\u003ctd\u003e450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLength\u003c\/th\u003e\n\u003ctd\u003e6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInsulation\u003c\/th\u003e\n\u003ctd\u003eR0.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDucting \u0026amp; Flexible Duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-450-x-6m-R0-6-HVACHub-tile.pdf?v=1795301595\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49095761920118,"sku":"HH-SA-PY6450","price":131.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9075534823542.jpg?v=1794802826"},{"product_id":"hh-insulated-flex-150-x-6m-r0-6","title":"Insulated Flexible Duct 150 x 6m R0.6","description":"\u003cp\u003eInsulated flexible duct on a 6 m roll, for heat pump and ventilation ductwork.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner in plain packaging. One freight charge per order.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInside diameter\u003c\/th\u003e\n\u003ctd\u003e150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLength\u003c\/th\u003e\n\u003ctd\u003e6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInsulation\u003c\/th\u003e\n\u003ctd\u003eR0.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDucting \u0026amp; Flexible Duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-150-x-6m-R0-6-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49095764705398,"sku":"HH-SA-PY6150","price":57.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9075535347830.jpg?v=1794802825"},{"product_id":"hh-insulated-flex-200-x-6m-r0-6","title":"Insulated Flexible Duct 200 x 6m R0.6","description":"\u003cp\u003eA 6 m roll of 200 mm insulated flexible duct for home and commercial heating, cooling and ventilation.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner in plain packaging. One freight charge per order.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInside diameter\u003c\/th\u003e\n\u003ctd\u003e200 mm; outside diameter about 225 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLength\u003c\/th\u003e\n\u003ctd\u003e6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eR-value\u003c\/th\u003e\n\u003ctd\u003eR0.6 (polyester insulation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInner core\u003c\/th\u003e\n\u003ctd\u003emetallised Mylar on a steel-wire helix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter jacket\u003c\/th\u003e\n\u003ctd\u003ereflective silver Mylar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012 and UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature range\u003c\/th\u003e\n\u003ctd\u003e−20 °C to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePressure range\u003c\/th\u003e\n\u003ctd\u003e−190 Pa to +1,200 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDucting \u0026amp; Flexible Duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-200-x-6m-R0-6-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49095764738166,"sku":"HH-SA-PY6200","price":57.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9075535380598.jpg?v=1794802825"},{"product_id":"hh-insulated-flex-250-x-6m-r0-6","title":"Insulated Flexible Duct 250 x 6m R0.6","description":"\u003cp\u003eInsulated flexible duct on a 6 m roll, for heat pump and ventilation ductwork.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner in plain packaging. One freight charge per order.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInside diameter\u003c\/th\u003e\n\u003ctd\u003e250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLength\u003c\/th\u003e\n\u003ctd\u003e6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInsulation\u003c\/th\u003e\n\u003ctd\u003eR0.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDucting \u0026amp; Flexible Duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-250-x-6m-R0-6-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49095765098614,"sku":"HH-SA-PY6250","price":72.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9075535446134.jpg?v=1794802825"},{"product_id":"insulated-flexible-duct-200mm-x-6m-r1-0","title":"Insulated Flexible Duct 200mm x 6m R1.0","description":"\u003cp\u003eCarries warm or cool air quietly from your heating or cooling system to each room. The built-in insulation keeps the air at the right temperature and helps stop condensation.\u003c\/p\u003e\n\u003cp\u003eDiameter: 200mm\u003c\/p\u003e\n\u003cp\u003eLength: 6m\u003c\/p\u003e\n\u003cp\u003eInsulation: R1.0\u003c\/p\u003e\n\u003cp\u003eConstruction: Reflective metallised polyester inner and outer layers, steel wire helix and polyester insulation\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-200-x-6m-R1-0-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49096425537654,"sku":"PYFB506200","price":87.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9075610714230.jpg?v=1794802825"},{"product_id":"insulated-flexible-duct-350mm-x-6m-r1-0","title":"Insulated Flexible Duct 350mm x 6m R1.0","description":"\u003cp\u003eCarries warm or cool air quietly from your heating or cooling system to each room. The built-in insulation keeps the air at the right temperature and helps stop condensation.\u003c\/p\u003e\n\u003cp\u003eDiameter: 350mm (about 400mm outer diameter with insulation)\u003c\/p\u003e\n\u003cp\u003eLength: 6m\u003c\/p\u003e\n\u003cp\u003eInsulation: R1.0\u003c\/p\u003e\n\u003cp\u003eConstruction: Reflective metallised polyester inner and outer layers, steel wire helix and polyester insulation\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-350-x-6m-R1-0-HVACHub-tile.pdf?v=1795301595\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49096440742006,"sku":"PYFB506350","price":131.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9075619922038.jpg?v=1794802826"},{"product_id":"acoustic-flexible-duct-150-x-3m-r1-0","title":"Acoustic Flexible Duct 150 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe acoustic lining soaks up fan and air noise, so it's a good choice near bedrooms and living areas. The thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2021, ASTM E477-99, AS\/NZS4859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e12 Micron Metallised PET Film, 12 Micron Clear PET Film, Water-based Fire Retardant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e150 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e200 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Acoustic-Flexible-Duct-150-x-3m-R1-0-HVACHub-tile.pdf?v=1795298102\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098526261366,"sku":"HH-SA-PYSF50150","price":57.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076122910838.jpg?v=1794802827"},{"product_id":"acoustic-flexible-duct-150-x-6m-r1-0","title":"Acoustic Flexible Duct 150 x 6m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe acoustic lining soaks up fan and air noise, so it's a good choice near bedrooms and living areas. The thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2021, ASTM E477-99, AS\/NZS4859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e12 Micron Metallised PET Film, 12 Micron Clear PET Film, Water-based Fire Retardant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e150 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e200 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Acoustic-Flexible-Duct-150-x-6m-R1-0-HVACHub-tile.pdf?v=1795298102\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098526294134,"sku":"HH-SA-PYSF506150","price":72.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076122943606.jpg?v=1794802826"},{"product_id":"acoustic-flexible-duct-200-x-3m-r1-0","title":"Acoustic Flexible Duct 200 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe acoustic lining soaks up fan and air noise, so it's a good choice near bedrooms and living areas. The thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2021, ASTM E477-99, AS\/NZS4859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e12 Micron Metallised PET Film, 12 Micron Clear PET Film, Water-based Fire Retardant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e200 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e250 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Acoustic-Flexible-Duct-200-x-3m-R1-0-HVACHub-tile.pdf?v=1795298102\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098526392438,"sku":"HH-SA-PYSF50200","price":72.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123041910.jpg?v=1794802827"},{"product_id":"acoustic-flexible-duct-200-x-6m-r1-0","title":"Acoustic Flexible Duct 200 x 6m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe acoustic lining soaks up fan and air noise, so it's a good choice near bedrooms and living areas. The thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2021, ASTM E477-99, AS\/NZS4859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e12 Micron Metallised PET Film, 12 Micron Clear PET Film, Water-based Fire Retardant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e200 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e250 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Acoustic-Flexible-Duct-200-x-6m-R1-0-HVACHub-tile.pdf?v=1795298102\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098526457974,"sku":"HH-SA-PYSF506200","price":102.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123107446.jpg?v=1794802827"},{"product_id":"acoustic-flexible-duct-250-x-3m-r1-0","title":"Acoustic Flexible Duct 250 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe acoustic lining soaks up fan and air noise, so it's a good choice near bedrooms and living areas. The thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2021, ASTM E477-99, AS\/NZS4859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e12 Micron Metallised PET Film, 12 Micron Clear PET Film, Water-based Fire Retardant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e250 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e300 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Acoustic-Flexible-Duct-250-x-3m-R1-0-HVACHub-tile.pdf?v=1795298260\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098526490742,"sku":"HH-SA-PYSF50250","price":72.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123140214.jpg?v=1794802826"},{"product_id":"acoustic-flexible-duct-250-x-6m-r1-0","title":"Acoustic Flexible Duct 250 x 6m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe acoustic lining soaks up fan and air noise, so it's a good choice near bedrooms and living areas. The thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2021, ASTM E477-99, AS\/NZS4859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e12 Micron Metallised PET Film, 12 Micron Clear PET Film, Water-based Fire Retardant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e250 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e300 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Acoustic-Flexible-Duct-250-x-6m-R1-0-HVACHub-tile.pdf?v=1795298260\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098526523510,"sku":"HH-SA-PYSF506250","price":116.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123172982.jpg?v=1794802827"},{"product_id":"acoustic-flexible-duct-300-x-3m-r1-0","title":"Acoustic Flexible Duct 300 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe acoustic lining soaks up fan and air noise, so it's a good choice near bedrooms and living areas. The thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2021, ASTM E477-99, AS\/NZS4859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e12 Micron Metallised PET Film, 12 Micron Clear PET Film, Water-based Fire Retardant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e300 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e350 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Acoustic-Flexible-Duct-300-x-3m-R1-0-HVACHub-tile.pdf?v=1795298260\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098526556278,"sku":"HH-SA-PYSF50300","price":102.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123205750.jpg?v=1794802826"},{"product_id":"acoustic-flexible-duct-300-x-6m-r1-0","title":"Acoustic Flexible Duct 300 x 6m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe acoustic lining soaks up fan and air noise, so it's a good choice near bedrooms and living areas. The thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2021, ASTM E477-99, AS\/NZS4859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e12 Micron Metallised PET Film, 12 Micron Clear PET Film, Water-based Fire Retardant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e300 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e350 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Acoustic-Flexible-Duct-300-x-6m-R1-0-HVACHub-tile.pdf?v=1795298260\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098526818422,"sku":"HH-SA-PYSF506300","price":131.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123271286.jpg?v=1794802827"},{"product_id":"acoustic-flexible-duct-350-x-3m-r1-0","title":"Acoustic Flexible Duct 350 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe acoustic lining soaks up fan and air noise, so it's a good choice near bedrooms and living areas. The thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2021, ASTM E477-99, AS\/NZS4859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e12 Micron Metallised PET Film, 12 Micron Clear PET Film, Water-based Fire Retardant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e350 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e400 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Acoustic-Flexible-Duct-350-x-3m-R1-0-HVACHub-tile.pdf?v=1795298260\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098526916726,"sku":"HH-SA-PYSF50350","price":116.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123369590.jpg?v=1794802826"},{"product_id":"acoustic-flexible-duct-350-x-6m-r1-0","title":"Acoustic Flexible Duct 350 x 6m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe acoustic lining soaks up fan and air noise, so it's a good choice near bedrooms and living areas. The thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2021, ASTM E477-99, AS\/NZS4859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e12 Micron Metallised PET Film, 12 Micron Clear PET Film, Water-based Fire Retardant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e350 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e400 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Acoustic-Flexible-Duct-350-x-6m-R1-0-HVACHub-tile.pdf?v=1795298260\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098526949494,"sku":"HH-SA-PYSF506350","price":161.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123402358.jpg?v=1794802827"},{"product_id":"acoustic-flexible-duct-400-x-3m-r1-0","title":"Acoustic Flexible Duct 400 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe acoustic lining soaks up fan and air noise, so it's a good choice near bedrooms and living areas. The thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2021, ASTM E477-99, AS\/NZS4859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e12 Micron Metallised PET Film, 12 Micron Clear PET Film, Water-based Fire Retardant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e400 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e450 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Acoustic-Flexible-Duct-400-x-3m-R1-0-HVACHub-tile.pdf?v=1795298260\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098526982262,"sku":"HH-SA-PYSF50400","price":131.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123435126.jpg?v=1794802826"},{"product_id":"acoustic-flexible-duct-400-x-6m-r1-0","title":"Acoustic Flexible Duct 400 x 6m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe acoustic lining soaks up fan and air noise, so it's a good choice near bedrooms and living areas. The thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2021, ASTM E477-99, AS\/NZS4859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e12 Micron Metallised PET Film, 12 Micron Clear PET Film, Water-based Fire Retardant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e400 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e450 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Acoustic-Flexible-Duct-400-x-6m-R1-0-HVACHub-tile.pdf?v=1795298260\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527047798,"sku":"HH-SA-PYSF506400","price":190.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123500662.jpg?v=1794802827"},{"product_id":"acoustic-flexible-duct-450-x-3m-r1-0","title":"Acoustic Flexible Duct 450 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe acoustic lining soaks up fan and air noise, so it's a good choice near bedrooms and living areas. The thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2021, ASTM E477-99, AS\/NZS4859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e12 Micron Metallised PET Film, 12 Micron Clear PET Film, Water-based Fire Retardant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e450 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e500 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Acoustic-Flexible-Duct-450-x-3m-R1-0-HVACHub-tile.pdf?v=1795298260\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527080566,"sku":"HH-SA-PYSF50450","price":161.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123533430.jpg?v=1794802826"},{"product_id":"acoustic-flexible-duct-450-x-6m-r1-0","title":"Acoustic Flexible Duct 450 x 6m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe acoustic lining soaks up fan and air noise, so it's a good choice near bedrooms and living areas. The thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2021, ASTM E477-99, AS\/NZS4859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e12 Micron Metallised PET Film, 12 Micron Clear PET Film, Water-based Fire Retardant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e450 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e500 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Acoustic-Flexible-Duct-450-x-6m-R1-0-HVACHub-tile.pdf?v=1795298260\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527113334,"sku":"HH-SA-PYSF506450","price":205.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123566198.jpg?v=1794802827"},{"product_id":"acoustic-flexible-duct-500-x-3m-r1-0","title":"Acoustic Flexible Duct 500 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe acoustic lining soaks up fan and air noise, so it's a good choice near bedrooms and living areas. The thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2021, ASTM E477-99, AS\/NZS4859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e12 Micron Metallised PET Film, 12 Micron Clear PET Film, Water-based Fire Retardant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e500 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e550 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Acoustic-Flexible-Duct-500-x-3m-R1-0-HVACHub-tile.pdf?v=1795298259\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527211638,"sku":"HH-SA-PYSF50500","price":205.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123664502.jpg?v=1794802826"},{"product_id":"insulated-flexible-duct-100-x-3m-r0-6","title":"Insulated Flexible Duct 100 x 3m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Polyester Insulation, Flame Resistant Adhesive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e100 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e125 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-100-x-3m-R0-6-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527277174,"sku":"HH-SA-PY100","price":29.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123730038.jpg?v=1794802810"},{"product_id":"insulated-flexible-duct-100-x-6m-r0-6","title":"Insulated Flexible Duct 100 x 6m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e100 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e125 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-100-x-6m-R0-6-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527309942,"sku":"HH-SA-PY6100","price":57.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123762806.jpg?v=1794802813"},{"product_id":"insulated-flexible-duct-125-x-3m-r0-6","title":"Insulated Flexible Duct 125 x 3m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e125 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e150 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-125-x-3m-R0-6-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527342710,"sku":"HH-SA-PY125","price":29.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123795574.jpg?v=1794802810"},{"product_id":"insulated-flexible-duct-125-x-6m-r0-6","title":"Insulated Flexible Duct 125 x 6m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e125 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e150 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-125-x-6m-R0-6-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527375478,"sku":"HH-SA-PY6125","price":57.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123828342.jpg?v=1794802825"},{"product_id":"insulated-flexible-duct-150-x-3m-r0-6","title":"Insulated Flexible Duct 150 x 3m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e150 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e175 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-150-x-3m-R0-6-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527441014,"sku":"HH-SA-PY150","price":29.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123893878.jpg?v=1794802810"},{"product_id":"insulated-flexible-duct-150-x-3m-r1-0","title":"Insulated Flexible Duct 150 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e150 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e200 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-150-x-3m-R1-0-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527473782,"sku":"HH-SA-PYFB50150","price":57.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123926646.jpg?v=1794802811"},{"product_id":"insulated-flexible-duct-150-x-6m-r1-0","title":"Insulated Flexible Duct 150 x 6m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e150 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e200 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-150-x-6m-R1-0-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527539318,"sku":"HH-SA-PYFB506150","price":72.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076123992182.jpg?v=1794802825"},{"product_id":"insulated-flexible-duct-200-x-3m-r0-6","title":"Insulated Flexible Duct 200 x 3m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e200 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e225 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-200-x-3m-R0-6-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527637622,"sku":"HH-SA-PY200","price":43.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124090486.jpg?v=1794802811"},{"product_id":"insulated-flexible-duct-200-x-3m-r1-0","title":"Insulated Flexible Duct 200 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e200 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e250 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-200-x-3m-R1-0-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527670390,"sku":"HH-SA-PYFB50200","price":57.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124123254.jpg?v=1794802811"},{"product_id":"insulated-flexible-duct-250-x-3m-r0-6","title":"Insulated Flexible Duct 250 x 3m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e250 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e275 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-250-x-3m-R0-6-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527703158,"sku":"HH-SA-PY250","price":43.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124156022.jpg?v=1794802811"},{"product_id":"insulated-flexible-duct-250-x-3m-r1-0","title":"Insulated Flexible Duct 250 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Commercial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e250 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e300 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-250-x-3m-R1-0-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527768694,"sku":"HH-SA-PYFB50250","price":57.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124221558.jpg?v=1794802811"},{"product_id":"insulated-flexible-duct-300-x-3m-r0-6","title":"Insulated Flexible Duct 300 x 3m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e300 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e325 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-300-x-3m-R0-6-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527801462,"sku":"HH-SA-PY300","price":43.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124254326.jpg?v=1794802811"},{"product_id":"insulated-flexible-duct-300-x-3m-r1-0","title":"Insulated Flexible Duct 300 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e300 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e350 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-300-x-3m-R1-0-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527834230,"sku":"HH-SA-PYFB50300","price":72.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124287094.jpg?v=1794802812"},{"product_id":"insulated-flexible-duct-300-x-6m-r0-6","title":"Insulated Flexible Duct 300 x 6m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e300 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e325 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-300-x-6m-R0-6-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527899766,"sku":"HH-SA-PY6300","price":87.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124352630.jpg?v=1794802825"},{"product_id":"insulated-flexible-duct-350-x-3m-r0-6","title":"Insulated Flexible Duct 350 x 3m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e350 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e375 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-350-x-3m-R0-6-HVACHub-tile.pdf?v=1795301309\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098527998070,"sku":"HH-SA-PY350","price":72.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124450934.jpg?v=1794802811"},{"product_id":"insulated-flexible-duct-350-x-3m-r1-0","title":"Insulated Flexible Duct 350 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e350 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e400 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-350-x-3m-R1-0-HVACHub-tile.pdf?v=1795301595\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098528030838,"sku":"HH-SA-PYFB50350","price":87.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124483702.jpg?v=1794802812"},{"product_id":"insulated-flexible-duct-350-x-6m-r0-6","title":"Insulated Flexible Duct 350 x 6m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e350 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e375 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-350-x-6m-R0-6-HVACHub-tile.pdf?v=1795301595\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098528063606,"sku":"HH-SA-PY6350","price":102.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124516470.jpg?v=1794802826"},{"product_id":"insulated-flexible-duct-400-x-3m-r0-6","title":"Insulated Flexible Duct 400 x 3m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e400 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e425 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-400-x-3m-R0-6-HVACHub-tile.pdf?v=1795301595\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098528096374,"sku":"HH-SA-PY400","price":72.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124549238.jpg?v=1794802812"},{"product_id":"insulated-flexible-duct-400-x-3m-r1-0","title":"Insulated Flexible Duct 400 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e400 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e450 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-400-x-3m-R1-0-HVACHub-tile.pdf?v=1795301595\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098528161910,"sku":"HH-SA-PYFB50400","price":102.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124614774.jpg?v=1794802812"},{"product_id":"insulated-flexible-duct-400-x-6m-r0-6","title":"Insulated Flexible Duct 400 x 6m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e400 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e425 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-400-x-6m-R0-6-HVACHub-tile.pdf?v=1795301595\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098528194678,"sku":"HH-SA-PY6400","price":116.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124647542.jpg?v=1794802826"},{"product_id":"insulated-flexible-duct-450-x-3m-r0-6","title":"Insulated Flexible Duct 450 x 3m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLength\u003c\/th\u003e\n\u003ctd\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-450-x-3m-R0-6-HVACHub-tile.pdf?v=1795301595\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098528260214,"sku":"HH-SA-ZZPY450","price":102.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124713078.jpg?v=1794802812"},{"product_id":"insulated-flexible-duct-500-x-3m-r1-0","title":"Insulated Flexible Duct 500 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e500 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e550 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-500-x-3m-R1-0-HVACHub-tile.pdf?v=1795301595\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098528358518,"sku":"HH-SA-PYFB50500","price":146.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124778614.jpg?v=1794802812"},{"product_id":"insulated-flexible-duct-500-x-6m-r1-0","title":"Insulated Flexible Duct 500 x 6m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e500 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e550 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-500-x-6m-R1-0-HVACHub-tile.pdf?v=1795301595\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098528391286,"sku":"HH-SA-PYFB506500","price":219.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124844150.jpg?v=1794802827"},{"product_id":"insulated-flexible-duct-550-x-3m-r0-6","title":"Insulated Flexible Duct 550 x 3m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e550 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e575 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-550-x-3m-R0-6-HVACHub-tile.pdf?v=1795301595\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098528424054,"sku":"HH-SA-PY550","price":161.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124876918.jpg?v=1794802812"},{"product_id":"insulated-flexible-duct-550-x-3m-r1-0","title":"Insulated Flexible Duct 550 x 3m R1.0","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eThe thicker insulation keeps more heat in, which suits long roof runs and colder South Island winters.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e550 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e600 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-550-x-3m-R1-0-HVACHub-tile.pdf?v=1795301595\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098528456822,"sku":"HH-SA-PYFB50550","price":219.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124909686.jpg?v=1794802812"},{"product_id":"insulated-flexible-duct-550-x-6m-r0-6","title":"Insulated Flexible Duct 550 x 6m R0.6","description":"\u003cp\u003eInsulated flexible duct carries warm or cool air from your heat pump or ventilation unit to each room without losing heat along the way, and it bends easily around joists and obstacles in the roof space.\u003c\/p\u003e\u003cp\u003eShips direct from our New Zealand warehouse partner. Check sizes against your system before ordering, or get in touch and we'll help you pick the right part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature Range (°C)\u003c\/th\u003e\n\u003ctd\u003e-20 to +80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperation Pressure (Pa)\u003c\/th\u003e\n\u003ctd\u003e-190 to +1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eAS 4254:2012, UL 181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eCommercial, Domestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eFoil Outer Jacket, Metallised-Foil Inner Core, Steel Wire, Flame Resistant Adhesive, Polyester Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eReflective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e550 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Duct Diameter (mm)\u003c\/th\u003e\n\u003ctd\u003e575 Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eDuct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFitting tips\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePull the duct out fully – compressed flex cuts airflow.\u003c\/li\u003e\n\u003cli\u003eKeep bends gentle and avoid kinks or sagging; support every 1.5m.\u003c\/li\u003e\n\u003cli\u003eFix each end with a duct tie over the inner liner, then tape the outer sleeve.\u003c\/li\u003e\n\u003cli\u003eIn NZ, keep insulated duct for runs through cold roof spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does R0.6 \/ R1.0 mean?\u003c\/strong\u003e\u003cbr\u003eIt's the insulation rating – R1.0 holds heat better in cold roof spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I cut it?\u003c\/strong\u003e\u003cbr\u003eYes – cut with a sharp knife and snips for the wire.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulated or uninsulated?\u003c\/strong\u003e\u003cbr\u003eUse insulated through unheated spaces; uninsulated for short runs inside the warm envelope.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/Insulated-Flexible-Duct-550-x-6m-R0-6-HVACHub-tile.pdf?v=1795301595\" target=\"_blank\" rel=\"noopener\"\u003eTech sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed a hand?\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@hvachub.co.nz\"\u003esales@hvachub.co.nz\u003c\/a\u003e with your size or a photo of the job and we'll help you pick the right part.\u003c\/p\u003e","brand":"HVAC Hub","offers":[{"title":"Default Title","offer_id":49098528522358,"sku":"HH-SA-PY6550","price":219.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/3811\/9542\/files\/hvachub-flex-9076124975222.jpg?v=1794802827"}],"url":"https:\/\/hvachub.co.nz\/collections\/duct-flexible-duct-insulated.oembed","provider":"HVAC Hub","version":"1.0","type":"link"}